Views:

The stove adjusts itself to heat levels 1, 2 and 3 and adapts the heat level every 15 minutes after the desired room temperature. If the room temperature is 1 degree greater or less than the desired room temperature, then the heat level will automatically adjust itself (maximum one level at the time). See below for detailed explanation:

  1. If the stove is off: If the desired room temperature that is selected is higher than the current room temperature the stove will turn on and start operating. The stove starts the ignition process and continues to operate at heat level 3 until the minimum smoke temperature for heat level 1 is reached. Go to point 3 for more detailed information.
  2. If the stove is operating and the room temperature adjustment function is selected on the app, and the smoke temperature has been greater than the minimum smoke temperature required for heat level 1, then the time is counted in which the room temperature is either more than 1 degree too low or too high. Go to point 3 for more detailed information.
  3. If the room temperature has a degree, that is more than 1 degree below the desired room temperature, then the stove will automatically move 1 operational heat level up after few seconds at the first level change. If the time in which the room temperature continues to be too low surpasses 10 minutes, then the control system will automatically increase the operational level an additional step up, i.e. from level 2 to 3. If the room temperature is more than 1 degree higher than the desired room temperature, the operational heat level is reduced 1 step down immediately. If the room temperature continues to be more than 1 degree above the desired room temperature for more than 10 minutes, then the control system will move an additional step down, i.e. from level 3 to 2 or from level 2 to 1.

The stove however only changes the heat level one time “immediately”, the other level changes are hereafter taken with a minimum of 10 minutes interval.